Rocscience acquires 3GSM. Read more

Search Results

Modify Load

The Modify Load option allows the user to modify the magnitude or orientation, of Distributed or Line loads, after they have been added to the model. Modify Load is available in the Loading menu, or as a right-click shortcut.

You CANNOT modify the LOCATION of a load, after it has been added to a model. If you need to change the location of a load, you will have to add a new load (and delete the old one, if necessary).

To modify a load:

  1. Select Modify Load from the Loading menu.
  2. Use the mouse to select a Distributed or Line load that you wish to modify. NOTE: you may only select ONE load at a time, to modify.
  3. Right-click the mouse and select Done Selection, or press Enter.
  4. You will see the Modify Distributed Load dialog or Modify Line Load dialog, displaying the orientation and magnitude parameters which define the load.
  5. In the dialog, enter the new magnitude and/or orientation parameters. You can use the Flip angle 180 degrees option if you need to reverse the direction of the load (see below for details). You can select Apply to view the changes without closing the dialog.
  6. Select OK when the desired parameters have been entered. The new load parameters will be in effect.

Flip angle 180 degrees

After adding a load, the orientation of the load may sometimes be opposite from the intended direction (i.e. 180 degrees off). For example, if you have used the Normal to Boundary or Horizontal orientation options, the default orientation chosen by Slide2 may be opposite to the intended direction. If this occurs, you can use the Modify Load option and select the Flip angle 180 degrees checkbox in the Modify Load dialog (Step 5). The load orientation will then be reversed by 180 degrees.

Right-Click Shortcut

The Modify Load option is also available as a convenient right-click shortcut. To do this:

  • Click the RIGHT mouse button on an existing distributed or line load (you can click anywhere on the arrows representing the load, but you cannot click on the numbers showing the load magnitude)
  • The load will be "selected" and a popup menu will appear. Select Modify Load from the popup menu.
  • Then follow steps 4 to 6 above, to modify the load magnitude and/or orientation.


Rocscience logo, click here to return to the homepage Portal Account Portal Account Log In Log Out Home Shopping Cart icon Click here to search our site Click here to close Learning Tech Support Documentation Info Chevron Delete Back to Top View More" Previous Next PDF File Calendar Location Language Fees Video Click here to visit Rocscience's LinkedIn page Click here to visit Rocscience's YouTube page Click here to visit Rocscience's X page Click here to visit Rocscience's Facebook page Click here to visit Rocscience's Instagram page Click here to visit Rocscience's Reddit page Bookmark Network Scroll down for more Checkmark Download Print Back to top Single User Multiple Users RSLog RocFall3 CPillar Dips EX3 RocFall RocPlane RocSlope RocSupport RocTopple RS2 RS3 RSData RSPile Settle3 Slide2 Slide3 SWedge UnWedge RocTunnel Commercial License Education License Trial License Shop safe & secure Money-back guarantee