Deterministic Analysis Results
The primary result from a CPillar Deterministic Analysis, is the pillar Factor(s) of Safety (FS). This is displayed at the top of the 3D Pillar View as shown below, and in the Sidebar.
The reported results depend on the Analysis Method selected in Project Settings.
Rigid:
- Shear Factor of Safety
Elastic:
- Shear Factor of Safety
- Elastic Buckling Factor of Safety
Voussoir:
- Shear Factor of Safety
- Arch Snap Thru Probability of Failure
- Compression Factor of Safety
All input parameters are assumed to be "exactly" known in a Deterministic analysis, so only a single pillar is analyzed. Deterministic Analysis results are available as described below.
Sidebar
A summary of analysis results and input data is displayed in the Sidebar Pillar Information panel.
To customize the display of information:
- Select the Filter List button in the Sidebar.
- In the Pillar Information Filter dialog, check/uncheck the entries in the list.
- Select OK to apply the filter.
Info Viewer
A comprehensive listing of all analysis input and output data, can be found in the Info Viewer. The Info Viewer data can be copied to the clipboard or saved to a file.