To define pile/forepole properties:

  1. Select the Support Support workflow tab workflow tab.
  2. Select Define Piles & Forepoles Define Piles & Forepoles icon from the toolbar or the Piles & Forepoles Piles & Forepoles icon sub-menu of the Support menu.
  3. TIP: you can also right-click on the viewing window and select Define Piles & Forepoles from the menu.

  4. You will see the Define Pile/Forepole Properties dialog with a list currently defined pile/forepole property types at the left of the dialog.
  5. To create a new pile property type select the Add button, or choose an existing pile from the list at the left of the dialog.
  6. Enter the required parameters for the pile/forepole.
  7. Repeat steps 4 and 5 as required to define different pile/forepole property types.

In the Pile/Forepole Properties dialog, the following parameters are used to define the pile/forepole properties. For more information on the numerical implementation of pile and forepole support in RS3 see the Piles and Forepoles document in the RS3 Theory section.

NOTE:

  • Piles and forepoles are based on beam elements with additional properties to account for the interface strength and stiffness. To define the beam properties use the Define Beam Properties option.
  • Piles/Forepoles can be added as individual (single) piles or pile patterns to selected faces or edges of external volume pieces.

Connection Type

This refers to the connection of the pile/forepole with a liner, which may represent a concrete raft for example.

  • Free - no forces or moment will be transferred from plate (raft) to the pile/forepole elements.
  • Hinged - connection can take forces only.
  • Rigid - connection can take forces and moment.

Shear and Normal Stiffness

Shear and normal stiffness of the interface between the soil and the beam element.

Beam Material

Piles/Forepoles in RS3 are based on beam elements. Therefore, you must choose the Beam Material from which the pile/forepole properties will be determined. To define the beam properties use the Define Beam Properties option. Beam properties include Area, I-min, I-max, E, and Poisson ratio.

Pile Properties

If the Pile/Forepole to be defined is a pile, select the Pile Properties checkbox, and specify the Base Normal Stiffness and Base Force Resistance.

If the Pile/Forepole to be define is a forepole, do not select the Pile Properties checkbox. For forepoles, Base Normal Stiffness and Base Force Resistance are not used, since forepoles are usually installed horizontally as tunnel roof support, with loading on the ends not considered.

BASE NORMAL STIFFNESS

With the Pile Properties checkbox selected, specify the Base Normal Stiffness taken from a pile load test to account for the interaction between pile tip and the soil at the tip.

BASE FORCE RESISTANCE

With the Pile Properties checkbox selected, specify the Base Force Resistance. To remain in the elastic region, the normal force, Fn, at the base of the pile must be less than the Base Resistance value: Fn < Base resistance value

Note that failure at the base only occurs when Fn > 0 (in compression).

Stage Properties

The properties of a Pile/Forepole can be modified at different stages of a multi-stage model, by using the Stage Properties option in the Define Pile/Forepole Properties dialog.

Most of the parameters entered in the Define Pile/Forepole Properties dialog can be increased or decreased by user-defined factors at different stages. For details about staging pile/forepole properties, see the Stage Material Properties topic, as the general procedure for staging properties is the same.

Skin and base Resistance

Failure criteria are used to determine if the pile/forepole interface behaves in the elastic or plastic region, as described below. For the elastic region, a small displacement occurs, depending on the stiffness values.

SKIN RESISTANCE

To remain in the elastic region, shear force, Fs, at a particular point must be less than the shear resistance: |Fs| < Tmax, where Tmax is the equivalent local skin resistance at that point.

Tmax is determined by one of the following criteria:

  • Linear: Tmax is distributed linearly from the top of the pile to the bottom of the pile.
  • C and Phi: Tmax = c + signma_n*tan(phi)
  • Multi-Linear: Tmax is distributed linearly for each section of the pile defined in the table.

SKIN RESISTANCE PROPERTIES (COHESION, FRICTION ANGLE)

Shear resistance of the interface between the pile and soil/rock.

SHEAR RESISTANCE CUTOFF

If the calculated shear resistance is larger than the cut-off value, the cut-off value will be used for the shear resistance (for pile in clays).

PERIMETER

Exposed circumference of the pile. Only used if Skin Resistance C and phi method is selected.

Force/Displacement

The pile elements are embedded in the model, meaning that they are not attached to mesh elements. If you wish to apply a force/moment directly to the pile/forepole, it needs to be applied in the Pile/Forepole Properties dialog. Select the Force/Displacement checkbox and enter the appropriate value of force or displacement and XYZ components defining the direction of the force or displacement.

Account Icon - click here to log in or out of your account Shopping Cart icon Click here to search our site Click here to close Learning Tech Support Documentation Info Chevron Delete Back to Top View More" PDF File Calendar Location Language Fees Video Click here to visit Rocscience's LinkedIn page Click here to visit Rocscience's YouTube page Click here to visit Rocscience's Twitter page Click here to visit Rocscience's Facebook page Click here to visit Rocscience's Instagram page Bookmark Network Scroll down for more Checkmark Download Print Back to top Single User Multiple Users CPillar Dips EX3 RocFall RocPlane RocSupport RocTopple RS2 RS3 RSData RSPile Settle3 Slide2 Slide3 SWedge UnWedge Commercial License Education License Trial License Shop safe & secure Money-back guarantee