Slide 5.0Features
FeaturesFeaturesDownloadsFAQs

Loading: Line Loads

Line loads can be applied to a Slide model with the Add Line Load option. Line loads represent concentrated forces, with units of FORCE / LENGTH, when considering the out-of-plane dimension.

The location of the line load on the slope is done interactively by either typing in the coordinates or using the mouse to track along currently defined boundaries. After the load location is entered, the orientation and magnitude are defined with the following dialog. The load orientation is easily defined using one of several automatic options (Normal, Vertical, Horizontal) or by specifying the angle.

Data input for a line load




A 15528 KN vertical line load (red arrow) on a large scale rock slope


Loading: Distributed Loads

Distributed loads (tractions, pressures) can be easily added to a model. The distribution of load can either be constant or triangular. If it is a constant distributed load, a single magnitude is defined while if it is triangular, the magnitude at each end of the distribution is entered.

A distributed load magnitude is defined as a FORCE per UNIT LENGTH (eg. kN/m), when considering the 2-dimensional problem. This represents a FORCE per UNIT AREA (eg. kN/m2) when considering the out-of-plane dimension.


Data input for a distributed load




A constant distributed load



A triangular distributed load


Loading: Seismic Loads

Pseudo-static seismic loads can be added to a Slide analysis by defining the seismic load coefficients in the horizontal and/or vertical directions. The driving force on each slice due to seismicity is then calculated by multiplying the slice weight by the seismic load coefficient.

The example below shows a coefficient of 0.15, however there are no limitations on the seismic coefficients that you can enter in Slide.

Data input for seismic loads




Example: Dam analysis incorporating seismicity. Maximum earthquake acceleration is 0.15g, analysis uses a seismic load coefficient in the horizontal direction equal to 0.15


Loading: Interactive Editing of Loads

All loads can easily be modified or deleted by placing the cursor over the load and clicking your right mouse button. This will display a popup menu that will give you the option of either modifying or deleting the load.

Right-click on a load to either modify or delete it



The dialog for modifying the load